SOLO 1000® Online Trouble-Shooting Guide
 |
SOLO
1000 ELECTRONIC SCALES: Our electronic scales sense weight
through a shear beam strain gauge load cell mounted in a hardware
assembly beneath the platform. The shear beam load cell accepts load
at one end of the beam and thus deflects (or strains) a Wheatstone
bridge within the load cell. This deflection causes a change in microvoltage
(millivolt / volt signal) proportional to the applied load, which
is displayed as a weight or volume on our multi-channel digital weight
indicator. |
Symptom:
DISPLAY WILL NOT CHANGE
Possible Cause: LOAD CELL / TARE ADJUST KNOB WIRING
This condition can be caused by an improper installation (single
channel or dual channel). When the
scale is initially installed, the load cell cable is sometimes disconnected
from the SOLO so that it can be run through conduit or a hole in a wall.
When reconnecting, you must make sure that both the Load Cell Cable and
the Tare Adjust Knob are connected to the same J1 connector terminal.
If the Tare Adjust knob wires have not been reconnected properly to Red,
Green and Black, this will sometimes cause the display to lock-up.
Symptom:
ERRATIC READINGS
Possible Cause: FRICTION OR BINDING
For any scale to operate properly, plumbing or other devices must not
restrain the tank or platform. In order to eliminate any friction or binding
in the system, all tank supply or feed connections
must be flexible. If there is any friction or binding in the tank
connections, fluctuations in readings may happen due to the load cell
being restrained from moving up and down freely as temperature and weight
changes.
|